Sponsored Links
-->

Friday, May 18, 2018

Electric Currents ~ wiring diagram components
src: farhek.com

Cardiac contractility modulation is a name of a therapy developed by Impulse Dynamics NV, who implements the therapy within its implantable devices, under the brand name CCM(TM). This therapy is intended for the treatment of patients with moderate to severe heart failure (NYHA class II-IV) with symptoms despite optimal medical therapy who can benefit from an improvement in cardiac output. The short- and long-term use of this therapy enhances the strength of ventricular contraction and therefore the heart's pumping capacity by modulating (adjusting) the myocardial contractility.

The Cardiac contractility modulation treatment is delivered by a pacemaker-like device that applies non-excitatory electrical signals NES, adjusted to and synchronized with the electrical action in the cardiac cycle. Other than a pacemaker, which delivers an electrical signal with the intention to result in cardiac contraction, the Cardiac contractility modulation treatment applies the NES, adjusted to and synchronized with the electrical action in the cardiac cycle.

In Cardiac contractility modulation therapy, electrical stimulation is applied to the cardiac muscle during the absolute refractory period. In this phase of the cardiac cycle, electrical signals cannot trigger new cardiac muscle contractions, hence this type of stimulation is known as a non-excitatory stimulation. However, the electrical signals increase the influx of calcium ions into the cardiac muscle cells (cardiomyocytes). In contrast to other electrical stimulation treatments for heart failure, such as pacemaker therapy or implantable cardioverter defibrillators (ICD), Cardiac contractility modulation does not affect the cardiac rhythm directly. Rather, the aim is to enhance the heart's natural contraction (the native cardiac contractility) sustainably over long periods of time. Furthermore, unlike most interventions that increase cardiac contractility, the Cardiac contractility modulation is not associated with an unfavorable increase in oxygen demand by the heart (measured in terms of Myocardial Oxygen Consumption or MVO2). This may be explained by the beneficial effect the therapy has in improving cardiac efficiency. A meta-analysis in 2014 and an overview of device-based treatment options in heart failure in 2013 concluded that Cardiac contractility modulation treatment is safe, that it is generally beneficial to patients and that the treatment increases the exercise tolerance (ET) and quality of life (QoL) of patients. Furthermore, preliminary long-term survival data shows that Cardiac contractility modulation is associated with lower long-term mortality in heart failure patients when compared with expected rates among similar patients not treated with Cardiac contractility modulation.


Video Cardiac contractility modulation



Medical uses

Approval

Based on the results of clinical trials, Cardiac contractility modulation devices are approved and available for clinical use in all European Union countries and in Australia, Turkey, India and Hong Kong, as well as in other countries that recognize CE marking for medical devices.

At the present time, Cardiac contractility modulation therapy is not approved for clinical use in the United States. However, a study has been initiated in order to obtain FDA approval, and continued access has been granted by the FDA

Indication

Based on the approval of Cardiac contractility modulation devices, the therapy is a treatment option for patients that are at least 18 years old who suffer from heart failure symptoms due to left ventricular systolic dysfunction (LVSD) despite adequate medical treatment. Further clinical research are under way to identify which patient group within the scope of the device approval benefits most from Cardiac contractility modulation treatment.

Criteria for the classification of patients with left ventricular systolic heart failure include the severity of the disease based on functional parameters (NYHA classification), the average percentage of blood volume ejected by the left ventricle with each heart beat (left ventricular ejection fraction or LVEF) and the duration of the QRS complex seen in the electrocardiogram (ECG). Most clinical studies on Cardiac contractility modulation therapy have involved heart failure patients who were classified initially as NYHA Class II, III or IV and had a normal QRS duration (QRS duration <= 120 ms). The efficacy of Cardiac contractility modulation on patients in an earlier stage of heart failure has not yet been studied.

A subsequent evaluation study (subgroup analysis) has already suggested a particular patient group that responds exceptionally well to Cardiac contractility modulation therapy. The patients were characterized by a disease severity of NYHA class III and a left ventricular ejection fraction of >= 25%.

Although studies on Cardiac contractility modulation therapy have focused on patients with a normal QRS duration (i.e. <= 120 ms), it is possible to use the therapy in patients who meet the treatment indication but who do not have a normal QRS duration.

A preliminary study has previously shown that Cardiac contractility modulation may be safe and effective in such patients who have not responded to cardiac resynchronization therapy (CRT).

Therapeutic gap

Cardiac resynchronization therapy (CRT; also known as biventricular pacing) has proven to be an effective treatment in heart failure. However, CRT is generally recommended exclusively for patients with a preserved sinus rhythm and a prolonged QRS complex (>= 120 ms) who also suffer from left bundle branch block (LBBB), or for patients without left bundle branch block but who have a preserved sinus rhythm and a QRS complex with a width of >= 150 ms. However, only 30-40% of all heart failure patients show such a prolonged QRS complex, and therefore the 60-70% of patients who have a normal QRS complex cannot be treated with CRT. In addition, around 30% of the patients eligible for CRT treatment do not respond to CRT.

Until recently, the only other available device-based treatment was the left ventricular assist device (LVAD). LVAD therapy is indicated in patients with severe illness and is associated with several hours of surgery (involving a cardiopulmonary bypass). It is usually considered as a therapy providing a "bridge to transplant" for heart failure patients classified as NYHA class IV, and is intended to support heart function until a heart transplant is received. Current research results suggest that the therapeutic gap described above could now be closed by the Cardiac contractility modulation therapy. Additionally, a long-term study showed that the Cardiac contractility modulation was able to stop the common and prognostically unfavorable long-term prolongation of QRS duration in heart failure patients. This result was interpreted as signaling the safety of the treatment and as an indicator that patients could benefit from Cardiac contractility modulation therapy in the long term. If the QRS-stabilizing effect were to be confirmed in further studies, the Cardiac contractility modulation would become the first device-based treatment for heart failure with the potential to halt QRS prolongation, a factor associated with a poor prognosis.

Recommendations

The guidelines issued by the European Society of Cardiology (ESC) in 2016, mention Cardiac contractility modulation therapy as a therapy option to be considered in selected group of patients with HF. Mostly these guidelines are endorsed by national cardiac societies in individual countries within the European Union.

Efficacy

Cardiac contractility modulation has proven to be effective and safe in randomized controlled trials involving several hundred patients.

The nature and extent of the effect of Cardiac contractility modulation have been the subject of numerous investigations. Although various individual publications, as well as one of two meta-analyses, have presented the efficacy and significant potential of Cardiac contractility modulation in the treatment of heart failure, medical evaluation of the therapy efficacy is not yet complete. Scientists point out, however, that this was also the case for CRT therapy when it was first introduced, advocating the provision of Cardiac contractility modulation to suitable patients before further studies are completed.

To date (February 2015), there are at least two meta-analyses studying the efficacy of Cardiac contractility modulation therapy on heart failure, a large number of review articles (e.g.) and at least two survey articles on device-based treatments of advanced heart failure which address cardiac contractility modulation. Furthermore, there are more than 70 individual publications focusing specifically on Cardiac contractility modulation therapy.

Further randomized controlled trials studying the effect of Cardiac contractility modulation on the progression of heart failure have been initiated and are currently (as of Feb 2015) recruiting patients.

Meta-analyses

Giallauria et al. evaluated the three randomized controlled trials (RCTs) currently available on Cardiac contractility modulation as a treatment for heart failure patients. The three trials included a total of 641 patients and assessed the effect of Cardiac contractility modulation either in comparison to a sham treatment or in comparison to the best medical treatment. In contrast to an earlier meta-analysis by Kwong et al. the study did not evaluate the data based on summarized results alone, but on the basis of the individual data sets of the 641 enrolled patients.

The study concluded that Cardiac contractility modulation significantly improved important markers of cardiac performance. These included the maximal oxygen uptake (peak VO2 or pVO2 - measured by ventilatory parameters during a cardiopulmonary exercise test), which is indicative of improved survival, and the 6-minute walk test. The quality of life of participating patients, measured by the Minnesota Living with Heart Failure Questionnaire (MLWHFQ), also improved significantly. However, both meta-analyses demanded additional and larger randomized controlled trials in order to evaluate the effect of the therapy more precisely.

Giallauria et al. describe the success of cardiac contractility modulation and the further potential of the therapy. Particular emphasis is given to the possibility that Cardiac contractility modulation therapy may close the therapeutic gap in heart failure treatment if previous study outcomes are confirmed.

Long-Term Survival Studies

As of February 2015, the effect of Cardiac contractility modulation therapy on the long-term mortality rates of heart failure patients has not been studied in a randomized controlled trial. Some preliminary single-center studies have been reported though. Kuschyk et al. evaluated the long-term efficacy and survival of patients with Cardiac contractility modulation. Their analysis included 81 patients with a disease severity of NYHA class II, III or IV and a mean follow-up of around 3 years. The analysis compared the observed mortality rate with the prediction of the Meta-analysis Global Group in Chronic Heart Failure (MAGGIC) model which is based on the records of over 39,000 heart failure patients. Unlike a previous long-term outcome study of Cardiac contractility modulation, this study was not limited by a widely heterogeneous group of patients.

Following long-term observation, the study concluded that Cardiac contractility modulation improved quality of life, exercise tolerance, NYHA class, left ventricular ejection fraction (LVEF) and brain natriuretic peptide (BNP) levels. Mortality rates were significantly lower than predicted at year 1, and lower than predicted but not statistically significant at year 3.

General

Heart failure is a chronic disease that usually progresses gradually. The rate of progression and the degree of symptoms of the disease varies between different patients. Cardiac contractility modulation therapy aims to treat heart failure through a medium- to long-term treatment, over the course of weeks and months.

According to large implanting clinics, after the implantation wound is healed, the lifestyle of a patient is not restricted by the implanted device. Leisure, travel (by car, train, ship or plane), hobbies and sex life will not be restricted. The patient may perceive an improved capacity for these activities and overall enhanced performance and exercise capacity in response to the actual therapy.


Maps Cardiac contractility modulation



Contraindications

In the past, the most important contraindication in Cardiac contractility modulation treatment was permanent and long-standing persistent atrial fibrillation. The signal application in current Cardiac contractility modulation devices was timed and triggered according to the electrical activity of the atrium. In atrial fibrillation, electrical activity in the atrium is severely disturbed and is therefore not a reliable basis for the triggering of Cardiac contractility modulation signals. This also applies to other diseases involving severe disturbance in electrical atrial sensing. Requests have been raised in scientific literature for an improved Cardiac contractility modulation algorithm which would allow the therapy to be delivered independently from any atrial signal. A pioneering study had shown that an improved Cardiac contractility modulation algorithm could make the therapy an effective treatment for patients with persistent atrial fibrillation. Following these study results the new generation was developed and can now offer Cardiac contractility modulation therapy also for patients with atrial fibrillation.

Other irregular rhythms, including frequent premature ventricular contractions (ventricular extra systoles) or a distinct signal transduction disorder in the heart (untreated AV block of more than 300 ms), may represent contraindications. CRT treatment should be considered in lieu of Cardiac contractility modulation in patients with left bundle branch block (LBBB) and a QRS duration of over 120 ms, or when the QRS duration is greater than 150 ms and independent of LBBB.

As with conventional pacemaker therapy, the Cardiac contractility modulation device cannot be implanted if the leads cannot be positioned appropriately in the heart. In cases where there is an artificial heart valve between the right atrium and ventricle (a mechanical prosthetic tricuspid valve), the valve function could be greatly affected by the ventricular leads. In some instances it may be impossible to guide the leads thorough the main veins in the upper half of the body to the heart due to venous thrombosis, for example VVI pacemakers, in the case of 100% stimulation, are also contraindicated.


Electric Currents ~ wiring diagram components
src: farhek.com


Side effects

The most frequently encountered adverse events related to Cardiac contractility modulation therapy are lead fracture or lead dislodgement. Other reported complications include:

  • Infection and bleeding at the IPG implantation site
  • Accumulation of fluid in the pericardium (pericardial effusion)

These side effects are similar to those that occur with other electrical stimulation therapies, such as pacemakers, CRT devices or ICD devices. Furthermore, recorded complications did not differ between patients with activated or deactivated Cardiac contractility modulation devices.

Overall, Cardiac contractility modulation treatment was demonstrated to have no negative impact on health markers.

Precautions

Similarly to patients with other electrical stimulation devices, patients with a Cardiac contractility modulation device must follow certain precautions arising from the device implantation and its function.

  • Electromagnetic fields: Strong electromagnetic fields can interfere with the function of the device. Most interference will lead to inhibition of Cardiac contractility modulation signal delivery. Once away from the field, the device will resume its normal function in most cases. The electromagnetic fields of household appliances are usually considered harmless.
  • Mobile phones: Similarly to other electrical stimulation devices, such as pacemakers, aside from a recommended safety distance of 10-15 cm (4-6 inches) between the device and mobile phones, there are no restrictions on the use of mobile phones.
  • Security checks: Full body or hand-held metal detectors, such as those used at airport security controls, do not usually affect the function of the device. However, where such detectors are used there are often signs warning people with cardiac pacemakers and defibrillators, and Cardiac contractility modulation patients are therefore advised to present their device ID. In these cases, the security check will typically continue with the use of a hand-held metal detector or by physical inspection.
  • Sports: All sports associated with increased stress on the arms or the chest, such as body building, martial arts or tennis, are usually not permitted. Diving is only permitted up to a depth of 5 meters due to the high pressure at greater depths.
  • Sports: All sports associated with increased stress on the arms or the chest, such as body building, martial arts or tennis, are usually not permitted. Diving is only permitted up to a depth of 5 meters due to the high pressure at greater depth.
  • Magnetic Resonance Imaging (MRI): Similarly to other electrical stimulation devices, such as pacemakers, Cardiac contractility modulation therapy is a contraindication for MRI, a medical imaging technique.

Figure 4 | Therapy With Cardiac Contractility Modulation ...
src: www.onlinejacc.org


Mechanism of action

The mechanism of action of Cardiac contractility modulation has been subject to continuous research since its initial discovery. Based on animal testing and experiments on human myocardial tissue obtained by biopsies, essential parts of the mechanism of action have been identified. According to current understanding (as of February 2015), the mechanism of action of Cardiac contractility modulation may be summarized in the following manner: The signals applied during the electrical non-excitatory state of the cardiac muscle cells (the absolute refractory period) cause an increase in myocyte calcium in the cytosol during systole. This increases the muscle contraction strength. Additionally, within minutes, cell metabolism and gene expression, which are typically abnormal in heart failure, improve towards their normal state. This beneficial effect occurs initially only in the area adjacent to the electrodes, but with time also spreads to remote areas of the cardiac muscle. Cardiac contractility modulation therefore restores the structure and function of damaged cells back towards their normal state. In some cases, disease-related changes in the ventricular heart structure can be partially reversed by Cardiac contractility modulation through a process known as reverse remodeling of the heart.


Electric Currents ~ wiring diagram components
src: farhek.com


Function

Composition

Cardiac contractility modulation devices are similar in structure to other implantable devices used for electrical stimulation of the heart, such as pacemakers or implantable cardioverter defibrillators (ICDs). The currently available system (as of February 2015) consists of four components, as described below.

    • Implantable Pulse Generator (IPG): The pulse generator generates the Cardiac contractility modulation's non-excitatory electrical signals. The IPGs currently in use are similar in dimension to a matchbox, but have a slightly larger surface and are a little more slender (approx. 6.5 cm x 4.7 cm x 1.2 cm or approx. 2 9/16" x 1 7/8" x 1/2"). The IPG is usually implanted in the chest subcutaneously (under the skin), below the right clavicle of the patient. In some cases, the IPG remains noticeable as a slight bulge under the skin. Pulse generators combining Cardiac contractility modulation therapy with the functionality of other electrical stimulation devices such as pacemakers or ICDs are not currently available, although the development of such a combined device has already been suggested in literature.
    • Leads: Currently available Cardiac contractility modulation delivery devices use three standard (commercially available) pacemaker leads. These leads are special medical wires that conduct the electrical signals between the pulse generator and the heart. During implantation, the leads are inserted into the subclavian vein below the clavicle or, less often, the cephalic vein or axillary vein. The leads are then advanced through the superior vena cava to their position in the right atrium or right ventricle. The lead in the right atrium detects atrial electric signals and transmits them to the pulse generator. The IPG processes the atrial signal and generates the signals which are transmitted to the right ventricle via two ventricular leads. The ventricular leads are positioned in the upper and middle region of the septum that separates the right ventricle from the left ventricle (interventricular septum). The leads themselves do not cause a change in the blood flow to the heart.
    • Battery charger: The battery charger ensures the power supply of the implantable pulse generator (IPG). Currently available battery chargers are used externally and are portable, allowing the patient to move freely while charging. The battery of the IPG can be charged wirelessly through the skin, without contact, since the charger operates by electromagnetic induction. Charging is carried out independently at home by the patient after having received the necessary briefing. One load cycle supplies the IPG with energy for about a week. This differs from conventional pacemaker and ICD devices which usually do not have a battery charging function and need to be surgically replaced prior to battery depletion.
    • Programming unit: The programming unit is used solely by the doctor for device check-ups or in case of technical problems. The stimulation signal of the pulse generator can be adjusted to the needs of each patient through the programming unit. For example, the programmer may be used to adjust the signal intensity and duration of the daily Cardiac contractility modulation application. The IPG can be programmed wirelessly through the skin by induction.

Cardiac contractility modulation signals

Cardiac contractility modulation acts on the cardiac muscle during the absolute refractory period via specific electrical signals generated by the pulse generator. Signals are applied approximately 30 ms after onset of the QRS complex (normal total QRS duration: <= 120 ms). The signal consists of two bi-phasic pulses with an amplitude of ± 7.7 V and with a total signal duration of about 20 ms.

Since Cardiac contractility modulation signals are delivered during the absolute refractory period of the cardiac cycle, they neither trigger muscle contractions nor cause activation of additional muscle fibers. Accordingly, the heart's electrical and mechanical activation sequence remains unchanged. As Cardiac contractility modulation signals contain around up to 500 times more energy than signals from conventional pacemakers, their peaks can easily be recognized in an electrocardiogram (ECG).

Implantation

The implantation of the pulse generator (IPG) and the corresponding Cardiac contractility modulation delivery leads is comparable to a pacemaker implantation. This sort of intervention is carried out approximately one million times per year worldwide. The implantation procedure is minimally invasive, lasts roughly 40 minutes and is usually carried out under local anesthesia. However, patients should fast ahead of the implantation due to possible complications which may result in a longer procedure and/or require longer anesthesia.

First, the doctor checks the function of the pulse generator and the leads, before positioning the leads in the heart. The positioning of the leads is verified by X-ray imaging and by the measurement of voltage and electric current through the leads (lead impedance).

Following successful positioning, the leads are connected to the pulse generator. A pocket is formed under the skin or chest muscle below the clavicle of the patient in order to implant the pulse generator. The IPG is inserted in the pocket and its function is tested. If the patient happens to have a pacemaker or implantable cardioverter defibrillator, the doctor and/or a trained technician ensures that there is no interference between the two devices by performing a "crosstalk check". Finally, the pocket is sutured and the wound is bandaged.

Following implantation, patients are usually monitored for a period of time to ensure that the Cardiac contractility modulation device functions properly before being discharged from hospital. Once the healing process is complete, there is no need for any precautionary measures concerning water contact with the device as it is completely under the skin. It is not problematic for patients to shower or swim with the device, providing their health condition permits these activities.

After discharge, treatment is continued under the care of an outpatient cardiologist. Check-ups are carried out after a few days, after a few weeks and then following the treating cardiologist's recommendation.

Maintenance

Aside from periodic battery charging (charging takes approximately 1 hour per week) and the surgical replacement needed after expiration of its battery life, the devices are maintenance-free. Nevertheless, the settings and function of the system must be checked and may be adjusted by a cardiologist from time to time. Battery chargers are equipped with a patient alert system which warns the patient to contact a physician in case of device malfunction or other functional abnormalities, such as low therapy delivery.

Interactions with other electrical stimulation treatments

Adverse interactions between Cardiac contractility modulation therapy and other electrical stimulation therapies have not been observed to date. Studies have shown that the therapy can be carried out simultaneously with a pacemaker and/or CRT treatment, and with or without an implantable cardioverter defibrillator (ICD), without causing disturbance to the individual therapies. As a result of these findings, the development of devices combining Cardiac contractility modulation and cardioverter defibrillation has been requested by some physicians in order to spare patients from the need for additional separate electrical stimulation devices and implantation procedures.

Referral and Reimbursement

Cardiac contractility modulation treatment is usually recommended by a cardiologist and the device may be implanted by a cardiac electrophysiologist. The treatment cost is covered both by statutory as well as private health insurance in Germany, Switzerland, Italy and Austria. The appropriate comparator for Cardiac contractility modulation therapy is failed Optimal Medical Therapy (OMT).


Figure 4 | Cardiac Contractility Modulation Electrical Signals ...
src: www.onlinejacc.org


History

Development of cardiac contractility modulation began in the late 1990s. Studies on individual cardiac muscle cells using a patch-clamp technique had already shown, in 1969, that a voltage applied during the absolute refractory period through leads between the interior of the cell and its outside environment increased the calcium influx through the cell membrane and improved the contraction of cardiac muscle cells. In 2001, scientists observed that a similar effect occurs even if the voltage is applied exclusively outside the cardiac muscle cells.[48] Additionally, it was observed that therapeutically useful effects on the cardiac muscle were achieved if the electrical signals were applied not only to single cells but to large areas using larger leads, as used in conventional cardiac pacemakers. The contractility of both a healthy heart and a damaged heart could be increased through application of appropriate signals during the absolute refractory period of the cardiac muscle cells.

An implantable Cardiac contractility modulation device was received by a patient for the first time in 2001. The first study on the therapeutic effects of in humans was presented in 2004. To date, more than 3,000 heart failure patients have been treated with Cardiac contractility modulation worldwide, including 641 patients under the study conditions recommended by the Cochrane Collaboration as being necessary for inclusion in a meta-analysis. Cardiac contractility modulation device implant was first successfully done in India in Royal Hospital,Trivandrum,Kerala,under the leadership of the Chief Cardiologist Dr. C. Bharath Chandran. Advocate Harishankar is the first person in India to get the CCM device implanted.


Electric Currents ~ wiring diagram components
src: farhek.com


See also

  • Heart
  • Cardiac cycle
  • Heart failure
  • Artificial cardiac pacemaker
  • Implantable cardioverter-defibrillator
  • NYHA classification
  • Cardiac resynchronization therapy

Anchoring Proteins as Regulators of Signaling Pathways ...
src: circres.ahajournals.org


External links

  • Current assessment of new device therapies for heart failure by the European Heart Rhythm Association (EHRA) - includes Cardiac contractility modulation

Figure 2 | Therapy With Cardiac Contractility Modulation ...
src: www.onlinejacc.org


References

Source of article : Wikipedia